INTUITY Messaging Solutions Release 4
MAP/5P Maintenance
585-310-186
Issue 3
October 1997
Replacing or Installing Circuit Cards
Page 5-36Installing a Remote Maintenance Circuit Card, Version 2
5
Installing a Remote Maintenance
Circuit Card, Version 2
The remote maintenance circuit card provides remote diagnostics of basic
components (Figure 5-16
). There is one remote maintenance circuit card
installed on the system.
Figure 5-23. Remote Maintenance Circuit Card
Types of Remote Maintenance Circuit Cards
The Lucent INTUITY system supports remote maintenance circuit cards:
With an internal modem (AYC54)
Without an internal modem (AYC55)
cdr2rmb LJK 043097
UPS
connector
Fan status
connector
BEC
enable
switch
Platform
reset
connector
Factory
use only