Installation in Unattended Mode 98
QSIGDialect:
Since several switches apply various Q-Sig protocol variants, it is important that your Q-Sig
configuration corresponds exactly to the switch that you are using. Set the ‘QSIGDialect’
that matches your switch and its Q-Sig standard. See the following table for correct values:
QSIGBriChannelId
Basic rate lines only. Set the channel identifier format for your PBX type. Possible settings
are:
• 0 (Standard): The channel ID is given in PRI format (three bytes).
• 1 (Short): The channel ID length is one byte.
Q-Sig PBX type Q-Sig standard Q-Sig dialect
Generic PBX Automatic 0
Generic PBX ISO 3
Generic PBX ECMA 1
Siemens HICOM 300 ECMAV1 1
Siemens HICOM 300 ECMAV2 3
Siemens HICOM 150 Automatic 0
Siemens HICOM 150 ISO 3
Siemens HICOM 150 ECMA 1
Alcatel 4400, 4410, 4200 Automatic 0
Alcatel 4400, 4410, 4200 ISO 9
Alcatel 4400, 4410, 4200 ECMA 8
Ericsson MD110 ISO 7
Ericsson MD110 ECMA 6
Ericsson BP250 Automatic 6
Lucent Definity Automatic 0
Lucent Definity ISO 3
Lucent Definity ECMA 1
matra6500 Automatic 0
matra6500 ISO 3
matra6500 ECMA 1
Nortel Automatic 0
Nortel ISO 3
Nortel ECMA 1