Across the Boards
Communications Device Drivers
Section 6 - MAINCON Driver Configuration
Page 266
cfSOFTWARE Confidential,
2000
6.19 MAINCON Panel D6, DEC VT220 (continued)
20. Warning Bell
When 1 (ON) is selected, an audible alarm will sound when an operation error occurs or the display
station received control-G code. If you select 0 (Off), and then the alarm will not be sounded when error
occurs or control-G received.
21. Numeric Keypad
When 0 (NORMAL) is selcted, the display station generates the corresponding ASCII character when a
numeric keypad key is pressed. If you choose 1, the display station generates the application control
function when a numeric keypad key is pressed.
22. Cursor Keys
When 0 (NORMAL) is selected, the display station generates the corresponding ASCII character when a
cursor key is pressed. If you select 1, the display station generates the application control function when a
cursor key is pressed.
23. User Defined Keys
When 1 (LOCK) is selected, the application program cannot define the function keys. If 0 (UNLOCK) is
selected the application will be able to (re-)define the keys. MAINCON allows function key macros to be
defined even if LOCK is chosen; however the VT220 driver will ignore macros.